How handle execute immediate results in a variable:
set serveroutput on
declare
tot number(10);
s varchar2(200);
begin
s:='select count(1) from all_users ';
execute immediate s into tot;
dbms_output.put_line('DB USERS Rows = '||tot);
end;
/